- New
- -15%
€76 Tax excluded
Orion 24/12-60 IP20 is a non-isolated DC-DC converter that supplies a fixed 13.2 V output at 60 A from a 24 V system, for high-power 12 V loads. It has fan-assisted cooling, and the remote on/off connector allows control via a low-power switch or the engine run/stop switch.
Victron Energy commercial warranty: 5 years for defects in materials and workmanship, handled through us as the seller. In addition to the legal guarantee. Conditions
Orion 24/12-60 IP20 is a non-isolated DC-DC converter that supplies a fixed 13.2 V output at 60 A from a 24 V system, for high-power 12 V loads. It has fan-assisted cooling, and the remote on/off connector allows control via a low-power switch or the engine run/stop switch.
Remote on/off connector
The remote on/off eliminates the need for a high current switch in the input wiring. The remote on-off can be operated with a low power switch or by the engine run/stop switch (see manual).
All models with adjustable output can also be used as a battery charger
For example to charge a 12 Volt starter or accessory battery in an otherwise 24V system.
All models with adjustable output can be paralleled to increase output current
Up to five units can be connected in parallel.
| Input voltage range | 18 … 35 V |
|---|---|
| Under-voltage shutdown | 14 V |
| Under-voltage restart | 18 V |
| Output voltage | 13.2 V |
| Continuous output current | 60 A |
| Output derating above 40 °C | 3 % |
| Off-load current | 20 mA |
| Maximum efficiency | 95 % |
| Fan-assisted cooling | Yes |
| Remote on/off terminal | Yes |
| Operating temperature range | -20 … 55 °C |
| DC connection terminals | Faston tab 6.3 x 0.8 mm |
| Remote on/off terminal connection | Removable multi-connector with screw terminals |
| Colour | Blue (RAL 5012) |
| Material | Aluminium |
| Protection category | IP20 |
| Weight | 0.85 kg |
| Height | 65 mm |
| Width | 88 mm |
| Depth | 185 mm |
| Safety | EN 60950 |
| Emission | EN-IEC 61000-6-3, EN 55014-1 |
| Immunity | EN-IEC 61000-6-2, EN-IEC 61000-6-1, EN 55014-2 |
We took these technical data from the manufacturer’s datasheet; transcription errors are possible. For 100% accuracy, please consult the attached datasheet.
Compatibility is calculated automatically from the manufacturers’ technical data and is for information only. For complex systems, we recommend having the configuration checked by a consultant before ordering. Details in the Terms and conditions