- New
- -15%
€1,649 Tax excluded
Lithium NG 25.6V/200Ah is a lithium iron phosphate (LiFePO4) battery with a nominal energy of 5120 Wh, designed for 24 V off-grid, residential and mobile systems. It features an integrated shunt, cell balancing and cell monitoring and an IP65 enclosure. It must be used with a Lynx Smart BMS NG, purchased separately, for monitoring via VictronConnect, a GX device or the VRM portal.
Victron Energy commercial warranty: 3 years for defects in materials and workmanship, handled through us as the seller. In addition to the legal guarantee. Conditions
Lithium NG 25.6V/200Ah is a lithium iron phosphate (LiFePO4) battery with a nominal energy of 5120 Wh, designed for 24 V off-grid, residential and mobile systems. It features an integrated shunt, cell balancing and cell monitoring and an IP65 enclosure. It must be used with a Lynx Smart BMS NG, purchased separately, for monitoring via VictronConnect, a GX device or the VRM portal.
The battery has integrated cell balancing and cell monitoring. The balancing and monitoring cables are daisy-chained and must be connected to a Lynx Smart BMS NG 500 A / 1000 A, mandatory and purchased separately. The BMS:
The battery firmware is updated automatically by the BMS.
The integrated shunt sends the battery voltage, current and temperature to the BMS, which calculates the state of charge and issues warnings and alarms. The BMS automatically detects the system voltage and the number of batteries connected in series, parallel or series-parallel.
Monitoring takes place via VictronConnect (Bluetooth built into the BMS), a GX device or the VRM portal: cell status and voltages, current and temperatures in real time.
| Nominal voltage | 25.6 V |
|---|---|
| Nominal capacity at 25 °C | 200 Ah |
| Nominal energy at 25 °C | 5120 Wh |
| Round trip efficiency | 92 % |
| Cycle life at 80 % DoD | 2500 cycles |
| Cycle life at 70 % DoD | 3000 cycles |
| Cycle life at 50 % DoD | 5000 cycles |
| Max continuous discharge current | 200 A (1C) |
| Max pulse discharge current (10 s) | 400 A (2C) |
| End of discharge voltage | 22.4 V |
| Charge voltage | 28-28.8 V |
| Float voltage | 27 V |
| Max continuous charge current | 200 A (1C) |
| Max pulse charge current (10 s) | 400 A (2C) |
| BMS | Lynx Smart BMS NG 500 A / 1000 A (M10 busbars), purchased separately |
| Cell measurements | Cell voltages and temperatures, battery current |
| BMS interface | Male + female cable with M8 circular connector, high-speed digital communication, 50 cm |
| Alarm | Pre-alarm contact on BMS |
| Bluetooth | In the BMS |
| Max batteries per BMS | 50 (up to 384 kWh per BMS) |
| Firmware updates | Automatically by the BMS |
| Repairable | Yes (cover removable with screws) |
| Operating temperature | Discharge: -20 °C to +50 °C, charge: +5 °C to +50 °C |
| Storage temperature | -45 °C to +70 °C |
| Humidity (non-condensing) | Max. 95 % |
| Protection class | IP65 |
| Mounting options | Strap or mounting brackets (brackets included) |
| Mounting on its side | Yes, but not with the terminals facing down |
| Self-discharge rate | ≤ 3 % per month at 25 °C |
| Power connection | M8 (threaded inserts and bolts) |
| Dimensions (h x w x d) | 235 x 648 x 162 mm |
| Weight (estimated) | 37 kg |
| Safety | Cells: UL1973, UL9540A, IEC62619; battery: IEC 62619 (pending), UL 2054 (certified with Lynx BMS NG) |
| EMC | EN 61000-6-3, EN 61000-6-2 |
| Automotive | ECE R10-6 |
| Performance | IEC 62620 |
We took these technical data from the manufacturer’s datasheet; transcription errors are possible. For 100% accuracy, please consult the attached datasheet.
Compatibility is calculated automatically from the manufacturers’ technical data and is for information only. For complex systems, we recommend having the configuration checked by a consultant before ordering. Details in the Terms and conditions