Cookie consent

We use cookies that the shop needs to work and, only with your consent, statistics and marketing cookies.

60 kW SOFAR hybrid inverter, three-phase, HV, HYD-60K-T1

€6,051 Tax included

€5,043 Tax excluded

HYD-60K-T1 is a 60 kW three-phase SOFAR hybrid inverter with 4 MPPT (160-950 V, 40 A per MPPT) and a 600-1000 V HV battery input. Battery charging is up to 60 kW (100 A), discharging up to 60 kW (100 A), and the backup output switches over in 4 ms. It is wall mounted, rated IP66 and weighs 75 kg.

Reference HYD-60K-T1

HYD-60K-T1 - 60 kW three-phase hybrid inverter for HV batteries

HYD-60K-T1 is a 60 kW three-phase hybrid inverter for commercial installations, with 4 MPPT and a port for a high-voltage battery (600-1000 V). It combines PV inversion, battery charging and backup supply in a single IP66 wall-mounted unit.

Main features:

  • Rated power: 60 kW (66 kVA maximum)
  • PV input: 4 MPPT, 160-950 V, 40 A per MPPT; recommended PV power 120 kWp
  • Battery: HV, 600-1000 V, charging up to 60 kW / 100 A
  • Battery discharge: up to 60 kW, 100 A
  • Backup supply: 4 ms switchover, peak of 1.5 times rated power for 10 s, 100 % unbalanced three-phase load
  • Maximum efficiency: 98.2 %
  • Protection: IP66, AFCI, PV type I+II and AC type II surge protection

The inverter connects to a SOFAR HV battery (600-1000 V) over CAN communication. The manual describes configurations with SOFAR CBS5000 batteries (5.12 kWh modules) and CBS8000 batteries (16 kWh modules). The battery is not included. Up to 6 inverters can run in parallel in grid-connected mode and up to 3 in off-grid mode, all of the same model and with the same battery configuration.

The unit has a port for a generator or for controlled loads (smartload), an LCD and an app for commissioning. Standard communication is RS485; Wi-Fi, 4G or LAN are optional modules. The operating temperature is -30 ... 60 °C, with derating above 45 °C.

Technical specifications

Number of MPPT4
Max. number of input strings per MPPT2
Recommended max. PV power120 kWp
Max. PV input voltage1000 V
Start-up voltage200 V
Rated input voltage600 V
MPPT voltage range160-950 V
Max. input current per MPPT40 A
Max. short-circuit current per MPPT50 A
Battery voltage range600-1000 V
Battery typeLithium-ion
BMS communicationCAN
Max. charging power60 kW
Max. charging current100 A
Max. discharging power60 kW
Max. discharging current100 A
Rated AC power60 kW
Max. apparent power66 kVA
Rated output current (380/400/415 V)91.2/86.6/83.5 A
Max. output current (380/400/415 V)100/95.3/91.8 A
Max. grid input current100 A
AC voltage and frequency3N~+PE, 380/400/415 V, 50/60 Hz
Peak power in backup mode1.5 times rated power, 10 s
Backup switching time4 ms
Unbalanced loadYes, 100 % three-phase
THDiunder 3 %
Power factor0.8 lagging - 0.8 leading
Max. MPPT efficiency99.9 %
Max. efficiency98.2 %
European efficiency97.5 %
Ingress protectionIP66
Operating temperature-30 ... 60 °C (derating above 45 °C)
Relative humidity5-95 %
Max. operating altitude4000 m (derating above 2000 m)
Standby self-consumptionunder 15 W
InstallationWall mounted
Dimensions (W x H x D)850 x 660 x 305 mm
Weight75 kg
CommunicationRS485; optional Wi-Fi, 4G, LAN

Data sheet

Reference
HYD-60K-T1
MPN
HYD-60K-T1
Product type
Inverter
Inverter type
Hybrid (built-in MPPT)
Phases
Three-phase
Power class
20+ kW
Continuous output power (VA, 25 °C)
66000 VA
Continuous output power (W, 25 °C)
60000 W
Peak power
1.5 times rated power, 10 s (backup)
Maximum efficiency
98.2 %
Zero-load power
under 15 W
Battery voltage
HV (high voltage)
Max. continuous discharge current
100 A
DC input voltage range
600-1000 V
Max. charge current
100 A
Max. PV input voltage
1000 V
Max. PV short-circuit current
50 A
Number of MPPT trackers
4
MPPT voltage range
160-950 V
AC output voltage
3N~+PE, 380/400/415 V
Output frequency
50/60 Hz
Max. AC input current
100 A
Parallel operation
Yes
Communication interfaces
RS485
Protections
AFCI, PV type I+II and AC type II surge protection, PV and battery reverse connection protection, output short circuit, overcurrent and overvoltage protection, insulation detection, residual current detection, anti-islanding, DC switch
Dimensions (H x W x D)
660 x 850 x 305 mm
Weight
75.0 kg
Ingress protection (IP)
IP66
Operating temperature
-30 ... 60 °C
Max. relative humidity
95 %
Standards and compliance
EN 62109, IEC 62109, IEC 62116, IEC 62920, IEC 61000, EN 55011, EN 50549-1, EN 50549-2, EN 50549-10, C10/11

We took these technical data from the manufacturer’s datasheet; transcription errors are possible. For 100% accuracy, please consult the attached datasheet.

Compatibility

Other compatible products

Compatibility is calculated automatically from the manufacturers’ technical data and is for information only. For complex systems, we recommend having the configuration checked by a consultant before ordering. Details in the Terms and conditions

Other products in the same category