- New
- -15%
€1,128 Tax excluded
Multi RS 48/6000/100-50 230V is a lightweight 48 V, 6 kVA high-frequency inverter/charger for stationary and mobile applications, the variant of the Multi RS Solar without integrated solar chargers. It supports Dynamic ESS, can be combined with another solar inverter, and all parameters are monitored on the built-in display or in the VictronConnect app.
Victron Energy commercial warranty: 5 years for defects in materials and workmanship, handled through us as the seller. In addition to the legal guarantee. Conditions
Multi RS 48/6000/100-50 230V is a lightweight 48 V, 6 kVA high-frequency inverter/charger for stationary and mobile applications, the variant of the Multi RS Solar without integrated solar chargers. It supports Dynamic ESS, can be combined with another solar inverter, and all parameters are monitored on the built-in display or in the VictronConnect app.
The Multi RS 48/6000 is a lightweight 48 V/6 kVA high-frequency inverter/charger, suitable for both stationary and mobile applications. It is the variant of the Multi RS Solar without the solar component and does not include integrated solar charge controllers.
In stationary applications it supports the Dynamic ESS function and gives you the flexibility to pair it with a solar inverter of a different type or power. It can also be used as a direct grid connection without batteries, so you can start simply and add storage later.
In mobile applications, the Multi RS offers a lightweight solution that keeps the batteries fully charged and, when there is surplus energy, can feed it back into the grid.
Monitor all parameters through the built-in display or the VictronConnect app, which also provides historical trend data, fast firmware updates and simple configuration tools. Connect it to a Cerbo GX for advanced ESS functions, including zero-export to prevent feed-in to the grid and backup mode to supply critical loads during power outages.
| PowerControl | Yes |
|---|---|
| PowerAssist | Yes |
| Parallel operation | Nu |
| Three-phase operation | Yes |
| Number of AC inputs | 1 |
| Transfer switch rated current | 50 A |
| Nominal battery voltage | 48 V |
| DC input voltage range | 38 … 62 V |
| AC output voltage | 230 V |
| Maximum continuous inverter current | 25 A |
| Frequency | 50 |
| Continuous output power at 25 °C (VA) | 6000 VA |
| Continuous output power at 25 °C (W) - A | 4600 W |
| Continuous output power at 25 °C (W) - B | 5200 W |
| Continuous output power at 40 °C | 4500 W |
| Continuous output power at 65 °C | 3000 W |
| Peak power (3 s) | 9000 W |
| Peak power (4 min) | 7000 W |
| Short-circuit current | 45 A |
| Maximum efficiency | 96.5 % |
| No-load consumption | 20 W |
| Shutdown on low battery | 37.2 V |
| Restart after low battery | 43.6 V |
| Charging voltage range | 36 … 60 V |
| Charge voltage in absorption | 57.6 V |
| Float charge voltage | 55.2 V |
| Maximum battery charge current | 88 A |
| Battery temperature sensor | Included |
| Battery voltage sensing (voltage sense) | Yes |
| Programmable relay | DC rating: 4A up to 35VDC and 1A up to 70VDC |
| Protections | Output short circuit, Overload, High battery voltage, Low battery voltage, Over-temperature, AC voltage at inverter output |
| Communication port | VE.Direct, VE.Can, Bluetooth |
| Bluetooth | Da, -4dBm, 2402 - 2480 MHz |
| General-purpose communication port | Da, 2x |
| Remote on/off | Yes |
| Fully programmable ports | Yes |
| Operating temperature range | -40 … 65 °C |
| Fan-assisted cooling | Yes |
| Maximum altitude | 2000 m |
| Maximum humidity | 95 % |
| Maximum AC input current | 50 A |
| AC input voltage range | 187 … 265 VAC |
| AC input frequency range | 45 … 65 Hz |
| Pollution degree | 2 |
| Auxiliary output | Yes |
| Number of AC outputs | 2 |
| AC connection terminals | Screw terminals 10 mm² (8 AWG) |
| Battery connection | M8 bolts |
| Colour | Blue (RAL 5012) and black (RAL 9017) |
| Material | Steel |
| Ingress protection | IP21 |
| Weight | 11.2 kg |
| Height | 462 mm |
| Width | 425 mm |
| Depth | 127 mm |
| Safety | EN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1, EN-IEC 62109-2, IEC 62040, IEC 62477 |
| Emission and immunity | EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, EN-IEC 61000-6-1, EN-IEC 61000-6-2, EN-IEC 61000-6-3 |
We took these technical data from the manufacturer’s datasheet; transcription errors are possible. For 100% accuracy, please consult the attached datasheet.
Compatibility is calculated automatically from the manufacturers’ technical data and is for information only. For complex systems, we recommend having the configuration checked by a consultant before ordering. Details in the Terms and conditions