Smart BatteryProtect 12/24V-220A - Battery protection against deep discharge
Smart BatteryProtect 12/24V-220A is a battery protection device that disconnects non-essential loads before the battery is fully discharged or can no longer crank the engine. Engage and disengage levels can be set via Bluetooth, or one of nine predefined levels can be selected with the programming pin. It handles 220 A continuous and 600 A peak.
Main features:
- Battery voltage: 12 V or 24 V, automatic detection
- Continuous and peak current: 220 A at 40 °C, peak 600 A (30 s)
- Programming: Bluetooth via VictronConnect with Instant Readout, or 9 preset levels
- Disconnect threshold: 10.5 V (12 V) / 21 V (24 V), default
- Over-voltage protection: load disconnected above 16.3 V (12 V), 32.6 V (24 V)
- Design: ignition-proof MOSFET switches, IP67 electronics
The Smart BatteryProtect disconnects the battery from non-essential loads before it is completely discharged (which would damage the battery) or before it has insufficient power left to crank the engine.
When using Bluetooth to program the Smart BatteryProtect any required engage/disengage levels can be set.
Alternatively, one of nine predefined engage/disengage levels can be set with the programming pin (see manual).
If required, Bluetooth can be disabled.
The Smart BatteryProtect is a uni-directional device. It can only deal with current in one direction, so either current to a load, or current from a charger, but not both currents at the same time. In addition to this, current only can only flow from the IN terminal to the OUT terminal. In case of use with a load, the battery connects to the IN terminal, and in case of use with a charger, the charger connects to the IN terminal.
Technical specifications
| Nominal battery voltage | 12V or 24V (automatic detection) |
|---|
| Operating voltage range | 6 … 35 V |
|---|
| Maximum continuous load current at 40 °C | 220 A |
|---|
| Maximum continuous load current at 60 °C | 132 A |
|---|
| Peak current rating | 600 A |
|---|
| Reverse current | No |
|---|
| Current consumption when on (Bluetooth disabled) | 1.2 mA |
|---|
| Current consumption when on (Bluetooth enabled) | 1.4 mA |
|---|
| Current consumption when off (Bluetooth disabled) | 0.7 mA |
|---|
| Current consumption when off (Bluetooth enabled) | 0.9 mA |
|---|
| Alarm output delay | 12 s |
|---|
| Maximum load on alarm output | 50 mA |
|---|
| Load disconnect delay | 90 s |
|---|
| Load reconnect delay | 30 s |
|---|
| Default disengage threshold (12 V) | 10.5 V |
|---|
| Default disengage threshold (24 V) | 21 V |
|---|
| Default engage threshold (12 V) | 12 V |
|---|
| Default engage threshold (24 V) | 24 V |
|---|
| Remote on/off terminal | Yes |
|---|
| Bluetooth | Yes |
|---|
| Protections | Output short-circuit |
|---|
| Operating temperature range | -40 … 50 °C |
|---|
| Battery and load terminals | M8 bolts |
|---|
| Remote control terminal | Screw terminal two pole |
|---|
| Alarm terminal | Screw terminal 3-pole |
|---|
| Protection category (connection area) | IP00 |
|---|
| Protection category (electronics) | IP67 |
|---|
| Weight | 0.8 kg |
|---|
| Height | 60 mm |
|---|
| Width | 123 mm |
|---|
| Depth | 121 mm |
|---|